CAT11-EN

VALVES AND SOLENOID VALVES Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 101 Construction characteristics Body, operator and end cover High resistance technopolymer Seals and poppets Oil resistant rubber (NBR) Piston and shaft Acetal resin Springs AISI 303 stainless steel Diaphragm Oil resistant rubber (NBR) Vacuum technology Catalogue Valves and solenoid valves poppet system Series T771 Use and maintenance These valves and solenoid valves have an average service life of approximately 10 - 15 million cycles under optimum conditions of usage. They do not need to be lubricated to operate well, but good filtration is recommended to prevent dirt accumulation inside. Ensure that the conditions of use are consistent with the indicated limits, pressure, temperature, etc. Take care to protect the discharge outlets of the valves in the presence of dirt and powder. When the self feeding version is used in the solenoid valves, check that the supply flow rate is greater than or equal to that of use, otherwise switch to the version with external pilot. The ordering codes refer to solenoid valves with “MP” or “MV” mechanicals mounted. The solenoid coils are not included and have to be ordered separately (see General Catalogue, Series 300, Section 1) with the exception of the bistable versions which already have solenoid coils 24V DC (N331.0A). Certified solenoid coils are also available (see Series 300).

RkJQdWJsaXNoZXIy NzYzOTY1