CAT11-EN

VACUUMGENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 31 Performance Charts Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 12 Noise (dBA) 76 Ordering code 19T06 .S.07.HV.ZZ Singlestagegenerators,robustandreliable,withcompactdimensionsandsuitable forapplications thatneed therequireddegreeofvacuum tobereachedquicklywith limitedair flows.Operating on the Venturi principle they have the vacuum connection orthogonal to the axis of supply and outlet. They can be connected directly to the suction cups and/or suction cup holder and can be applied in any position. 22 24 61 7 1 4 3 14.2 2 2 Ø 3.2 1 3 2 Tube 6 Tube 6 Tube 6 -95 -85 -75 -65 -55 -45 -35 -25 -15 -5 0 1 2 3 4 5 6 7 8 9 10 15 20 25 30 35 40 45 50 0 1 2 3 4 5 6 7 8 9 5,0 5,5 6,0 6,5 7,0 7,5 8,0 8,5 9,0 9,5 10,0 10,5 0 1 2 3 4 5 6 7 8 9 500 2000 3500 5000 6500 8000 9500 11000 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 0 1 2 3 4 5 6 7 8 9 10 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 3bar 4bar 5bar 6bar 3bar 4bar 5bar 6bar Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Single stage vacuum generator T06 Single stage vacuum generators Series 1900 Vacuum technology Catalogue Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 36 87 91 Intake flow rate (l/min) 10 10 10 Air consumption (l/min) 22 30 38

RkJQdWJsaXNoZXIy NzYzOTY1