CAT11-EN

VACUUM GENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 33 Performance Charts Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 55 90 88 Intake flow rate (l/min) 22 22 20 Air consumption (l/min) 51 72 91 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 15 Noise (dBA) 94 Ordering code 19T06.S.10.HV.ZY Single stage generators, robust and reliable, with compact dimensions and suitable for applications which need the required degree of vacuum to be reached quickly with limited air flows. Operating on the Venturi principle they have the vacuum connection orthogonal to the axis of supply and outlet. They can be connected directly to the suction cups and/or suction cup holder and applied in any position. Tube 6 Tube 6 Tube 8 Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Single stage vacuum generator T06 Single stage vacuum generators Series 1900 Vacuum technology Catalogue