VACUUMGENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 37 Performance Charts Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 35 66 85 Intake flow rate (l/min) 6 8 7 Air consumption (l/min) 2 8 11 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 15 Ordering code 19M05.S.05.SS.00 Single stage generators, robust and reliable, with compact dimensions and suitable for applications which need the required degree of vacuum to be reached quickly with limited air flows. Operating on the Venturi principle they have the vacuumconnection orthogonal to the axis of supply and outlet. They can be connected directly to the suction cups and/or suction cup holder and applied in any position. 2 1 22 3 30 0 1 5 1 5 . 7 3 1 20 12 Ø3.5 5 . 3 Ø 3.5 (n°2) M5 (n°3) -95 -85 -75 -65 -55 -45 -35 -25 -15 -5 0 1 2 3 4 5 6 7 8 9 1,0 2,5 4,0 5,5 7,0 8,5 10,0 11,5 13,0 14,5 16,0 17,5 0 1 2 3 4 5 6 7 8 9 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0 7,5 8,0 8,5 0 1 2 3 4 5 6 7 8 9 500 3000 5500 8000 10500 13000 15500 18000 20500 23000 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 3bar 4bar 5bar 6bar 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 -70 -60 -50 -40 -30 -20 -10 0 3bar 4bar 5bar 6bar Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Single stage vacuum generator M5 Single stage vacuum generators Series 1900 Vacuum technology Catalogue