CAT11-EN

VACUUMGENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 38 Performance Charts Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 53 82 78 Intake flow rate (l/min) 13 14 12 Air consumption (l/min) 11 24 36 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 24 Ordering code 19M05.S.08.SS.L0 Single stage generators, with operation based on the Venturi principle; their main feature is the presence of feed pressure and connection for the vacuumon the same axis. Thismakes it possible to connect the suction cups directly to the generator or through the suction cup holder, so therefore still on the same axis with obvious advantages in terms of system layout and simplicity. The outlet connection has a female thread G 1/8". 1 2 3 18 5.03 G1/8" Ø 8.71 5 M 30 Ø 19 13.5 "4/1 G -95 -85 -75 -65 -55 -45 -35 -25 -15 -5 0 1 2 3 4 5 6 7 8 9 5 10 15 20 25 30 35 40 45 50 0 1 2 3 4 5 6 7 8 9 9,0 9,8 10,5 11,3 12,0 12,8 13,5 14,3 15,0 0 1 2 3 4 5 6 7 8 9 200 2700 5200 7700 10200 12700 15200 17700 20200 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 bar 4bar 5bar 6bar 0 1 2 3 4 5 6 7 8 9 10 11 12 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 3 3bar 4bar 5bar 6bar Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Accessories 19S18.S Silencer G1/8” Single stage vacuum generator M5 Vacuum technology Catalogue Single stage vacuum generators Series 1900

RkJQdWJsaXNoZXIy NzYzOTY1