CAT11-EN

VACUUM GENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 39 Accessories 19S18.S Silencer G1/8” Performance Charts Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 53 82 78 Intake flow rate (l/min) 13 14 12 Air consumption (l/min) 11 24 36 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 26 Ordering code 19M18.S.08.SS.L0 Single stage generators, with operation based on the Venturi principle; their main feature is the presence of feed pressure and connection for the vacuum on the same axis. This makes it possible to connect the suction cups directly to the generator or through the suction cup holder, so therefore still on the same axis with obvious advantages in terms of system layout and simplicity. The outlet connection has a female thread G 1/8". 3 2 1 18 5.03 G1/8" 8.71Ø "8/1G 35 19 Ø13.5 "4/1G -95 -85 -75 -65 -55 -45 -35 -25 -15 -5 0 1 2 3 4 5 6 7 8 9 5 10 15 20 25 30 35 40 45 50 0 1 2 3 4 5 6 7 8 9 9,0 9,8 10,5 11,3 12,0 12,8 13,5 14,3 15,0 0 1 2 3 4 5 6 7 8 9 200 2700 5200 7700 10200 12700 15200 17700 20200 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 0 1 2 3 4 5 6 7 8 9 10 11 12 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 3 bar 4 bar 5 bar 6 bar 3 bar 4 bar 5 bar 6 bar Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Single stage vacuum generator G1/8” Single stage vacuum generators Series 1900 Vacuum technology Catalogue