CAT11-EN

VACUUMGENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 60 Performance Charts Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 40 88 86 Intake flow rate (l/min) 57 95 112 Air consumption (l/min) 44 75 109 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 132 Ordering code 19M38.M.12.SS.00 As a function of the modules (nozzles 2-4- 6-8) used, offer exactly the right performance for the most varied of industrial applications. They ensure a low level of noise thanks to the sound- absorbent material inside of them. 2 23 1 41 79.5 5 . 9 3 8 4 Ø4.5(n°2) 5 . 5 2 5 . 5 1 13 ” 8 / 1G G3/8” -95 -85 -75 -65 -55 -45 -35 -25 -15 0 1 2 3 4 5 6 7 8 9 50 800 1550 2300 3050 3800 4550 5300 6050 6800 7550 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 0 8 15 23 30 38 45 53 60 68 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 15 25 35 45 55 65 75 85 95 105 115 125 0 1 2 3 4 5 6 7 8 9 20 32 44 56 68 80 92 104 116 128 140 0 1 2 3 4 5 6 7 8 9 3 4 5 6 bar bar bar bar 3bar 4bar 5bar 6bar Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Multistage vacuum generator G3/8” Vacuum technology Catalogue Multistage vacuum generators Series 1900