CAT11-EN

VACUUMGENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 61 Performance Charts Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 40 86 83 Intake flow rate (l/min) 90 131 140 Air consumption (l/min) 57 94 133 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 1 ... 8 Temperature (°C) -10 ... +80 Weight (g) 178 Ordering code 19M38.M.15.SS.00 As a function of the modules (nozzles 2-4- 6-8) used, offer exactly the right performance for the most varied of industrial applications. They ensure a low level of noise thanks to the sound- absorbent material inside of them. Ø4.5(n°2) 2 1 23 41 79.5 5 . 9 3 8 4 4 3 4 2 21.5 ” 8 / 1G G3/8” -95 -85 -75 -65 -55 -45 -35 -25 -15 0 1 2 3 4 5 6 7 8 9 30 45 60 75 90 105 120 135 150 165 0 1 2 3 4 5 6 7 8 9 50 800 1550 2300 3050 3800 4550 5300 6050 6800 7550 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 0 8 15 23 30 38 45 53 60 68 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 20 35 50 65 80 95 110 125 140 155 0 1 2 3 4 5 6 7 8 9 3bar 4bar 5bar 6bar 3bar 4bar 5bar 6bar Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Multistage vacuum generator G3/8” Multistage vacuum generators Series 1900 Vacuum technology Catalogue

RkJQdWJsaXNoZXIy NzYzOTY1