VACUUM GENERATORS Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 78 Performance Charts 3 2 2 2 1 Operational characteristics Inlet pressure (bar) 2 4 6 Degree of Vacuum (-kPa) 40 86 84 Intake flow rate (l/min) 90 150 195 Air consumption (l/min) 76 135 180 Technical characteristics Fluid Unlubricated filtered air Pressure (bar) 0 ... 6 Inlet and release solenoid valve function N.C. Power consumption 4 Watt Supply voltage 24 VDC Solenoid valve - IP Rating IP65 Vacuum switch output 2 PNP Vacuum switch - IP Rating IP40 Temperature (°C) -10 ... +60 Weight (g) 537 Pressure (bar) Pressure (bar) Flow rate (l/min) Time (ms) Flow rate (l/min) Flow rate (l/min) Pressure (bar) Degree of vacuum (kPa) Degree of vacuum Air intake Emptying time (1 L.) Intake flow rate Degree of vacuum (kPa) Degree of vacuum (kPa) Air consumption Modular multifunction vacuum generator Vacuum technology Catalogue Modular multifunction vacuum generators Series 1900 10 54 Ordering code 19M14.M.18.ME. O O OPTIONS ED Solenoid valves + vacuum switch cable 2 Mt. EF Solenoid valves + vacuum switch cable 30 cm and connector M8 01 Solenoid valve without vacuum switch 02 Vacuum switch without back pressure valve 04 Without vacuum switch and back pressure valve 05 Vacuum switch cable 30 cm and connector M8 without back pressure valve