153 PROCESS AUTOMATION TECHNOLOGY Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Valves and solenoid valves with “Namur” interface Series 515 High Performance Process automation technology Catalogue Order codes Connections 5 : G1/4” - supplied without plate 7 : 1/4” NPT - supplied without plate Function and version 52.00.16: 5 ways - Pneumatic-Differential 52.00.18: 5 ways - Pneumatic-Pneumatic 52.00.19: 5 ways - Pneumatic-Spring 52.00.35: 5 ways - Solenoid-Solenoid 52.00.36: 5 ways - Solenoid-Differential 52.00.39: 5 ways - Solenoid-Spring 51 5 . B04 52.00.39 Model : Standard valve X : ATEX valve (-20°C ... +40°C) - only with solenoid coils “B##”,“C##” e “X##” (-30°C ... +50°C) - only with solenoid coils “MHC”,“MH#” . Temperature options : Standard valve (-10°C ... +50°C) LT : Low temperature (-30°C ... +50°C) Voltages Valve marking with ATEX solenoid coil Protection method of the ATEX solenoid coil B00: Ø10 stem without solenoid coil to be used with the following solenoid coils / B04: 12 VDC - for all models Ex ec Ex tc B05: 24 VDC - for all models B09: 24 VDC (2W) - only for standard model B56: 24 VAC (50-60 Hz) - for all models B57: 110 VAC (50-60 Hz) - for all models B58: 230 VAC (50-60 Hz) - for all models C04: 12 VDC - for all models C05: 24 VDC - for all models C09: 24 VDC (2W) - only for standard model C56: 24 VAC (50-60 Hz) - for all models C57: 110 VAC (50-60 Hz) - for all models C58: 230 VAC (50-60 Hz) - for all models F00: Ø9 stem without solenoid coil to be used with the following solenoid coils / X05: 24 VDC - only for ATEX model Ex mb X56: 24 VAC (50-60 Hz) - only for ATEX model X57: 110 VAC (50-60 Hz) - only for ATEX model X58: 230 VAC (50-60 Hz) - only for ATEX model MHC: 32 VDC T6 - only for ATEX model complete with connector Ex ia MH4: 32 VDC T4 - only for ATEX model Ex ia MH6: 32 VDC T6 - only for ATEX model Voltages Valve marking with FM solenoid coil L04: 12 VDC - only for FM APPROVED model L05: 24 VDC - only for FM APPROVED model L39: 120 VAC - only for FM APPROVED model L41: 240 VAC - only for FM APPROVED model FM APPROVED valve (-20°C ... +50°C) - only with solenoid coils “L##” II 2G Ex h IIC T5 Gb X II 2D Ex h IIIC T96°C Db X : II 3G Ex h IIC T4 Gc X II 3D Ex h IIIC T120°C Dc X IP65 : II 2G Ex h IIC T5 Gb X II 2D Ex h IIIC T96°C Db X : II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T135°C Db X IP65 : II 2G Ex h IIB/IIC T4 Gb X II 2D Ex h IIIC T130°C Db X IP65 : II 2G Ex h IIB/IIC T4 Gb X : Example : 515.52.00.39.B04 : Standard valve, G1/4” connections supplied without plate, solenoid-spring 5 ways, 12 VDC solenoid coil
RkJQdWJsaXNoZXIy NzYzOTY1