CAT16-EN

72 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice PROCESS AUTOMATION TECHNOLOGY Operational characteristics Maximum working pressure (bar) Flow rate at 6 bar with Δp=1 (Nl/min) Connections Weight (g) Cv kv 10 1000 1/4” NPT 1500 1,02 15,15 Operational characteristics Maximum working pressure (bar) Flow rate at 6 bar with Δp=1 (Nl/min) Connections Weight (g) Cv kv 10 1000 1/4” NPT 2600 1,02 15,15 Ordering code SS1432CAT01L T TENSION 1= 24 V DC 2= 24 V AC (50/60 Hz) 3= 110 V AC (50/60 Hz) 4= 220 V AC (50/60 Hz) Ordering code SS1432CATATL T TENSION 1= 24 V DC 2= 24 V AC (50/60 Hz) 3= 110 V AC (50/60 Hz) 4= 220 V AC (50/60 Hz) Ø5.2 Ø5.2 26 Ø5.2 15 15 33 60 110.4 8 50 85.4 143.4 53 46.5 71.1 117.6 53 35 74.7 Ø52 72Ø Exhaust 3 1/4” NPT Input 1 1/4” NPT Output 2 1/4” NPT Ground Ø5.2 Ø5.2 26 Ø5.2 15 15 60 60 110.4 110.4 50 85.4 85.4 46.5 71.1 53 117.6 53 46.5 71.1 117.6 74.7 Ø52 72Ø 74.7 Ø52 72Ø 220.7 Input 1 1/4” NPT Exhaust 3 1/4” NPT Output 2 1/4” NPT Ground Minimum piloting pressure 2,5 bar Fluid: Filtered air. No lubrication needed, if applied it shall be continuous. Inert Gas. Sweet gas (natural). Minimum piloting pressure 2,5 bar Fluid: Filtered air. No lubrication needed, if applied it shall be continuous. Inert Gas. Sweet gas (natural). Solenoid-spring valve Solenoid-solenoid valve Process automation technology Catalogue S.V. 3/2, 1/4” NPT - For safe area with IP66 stainless steel housing Series Steel line 2 1 3 2 1 3

RkJQdWJsaXNoZXIy NzYzOTY1