AUTOMOTIVE CATALOGUE

Technical information are provided for informative purpose only and can be subject to change without prior notice 147 Automotive Catalogue Locating FT-Series LOCATING Size 50 mm • Max deflection • Air consumption Air consumption for complete cycle REV. 00 - 18/06/2015 Thrust force 4900 N Pull force 2000 N Max distance from the load centre to the rod 200 mm • Functional data (at 5 bar / 72.5 psi) • Cycle time for max stroke < 0.8 s NO flow valve required Stroke Load (kg) Load position B deviation (mm) Load position C deviation (mm) 40 mm 0.5 0.001 0.002 1 0.001 0.002 1.5 0.001 0.002 2 0.001 0.002 2.5 0.001 0.004 3 0.001 0.004 3.5 0.002 0.004 4 0.002 0.004 0 0 5 10 15 20 Air consumption (Nl) Stroke (mm) 25 30 35 40 45 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 Air consumption (Nl/min) at 2 bar Air consumption (Nl/min) at 5 bar Air consumption (Nl/min) at 8 bar The thrust and pull forces (retraction) are only available with the last 2 mm stroke of working (extracting) position. In the other range of the stroke, the forces are 30% of the above values. Load position B Horizontal mounting position of the retractable locating pin/load centre at 100 mm from the rod axis Load position C Vertical mounting position of the retractable locating pin/load centre at 100 mm from the rod axis 100 mm 100 mm

RkJQdWJsaXNoZXIy NzYzOTY1