Size 40 mm Technical information are provided for informative purpose only and can be subject to change without prior notice 158 Functional charts J-Series Pneumatic gripper clamps 0 0 5 10 15 30 Air consumption (Nl) Opening angle (°) 45 60 75 90 105 120 135 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Air consumption (Nl) at 2 bar / 30 psi Air consumption (Nl) at 5 bar / 72.5 psi Air consumption (Nl) at 8 bar / 115 psi • Air consumption / Complete cycle (opening and closing) REV. 00 - 17/06/2015 • Cycle time for max opening angle < 0.8 s NO flow valve required HANDLING Technical features Manual release button to open the linkage when air pressure is removed during setup. Pneumatic ports on both sides of the cylinder. Operating features Operating pressure from 2 to 8 bar / from 30 to 115 psi Lubrication all the devices are lubricated for life at the factory. Inline air lubrication isn’t required • Clamping moment (at 5 bar / 72.5 psi) 50 N m / 36,87 lb·ft • Holding moment 75 N m / 55,31 lb·ft The above data are meant for correct working conditions of the clamp with the same performance level during its life time. For applications which exceed the above data, please contact our sales representatives. Ordering string 40 E G 1 2 A J J-Series VERSION J = R etractable locating pin package with dual rod P E OPERATION SENSOR 40 = Ø 40 mm E = electronic sensor with M12 swivel connector - PNP A = electronic sensor with M12 swivel connector - NPN N = no sensor B = electronic sensor with M8 swivel connector - PNP G PORTS G = G thread – BSPP 2 1 CLAMP ARM TYPE ARM MOVEMENT 2 = 2 pairs of knurled tips (not included in the scope of the supply) 1 = upper jaw A ARM MATERIAL A = aluminum S = steel 40 SIZE P = pneumatic D = pneumatic with manual operation J P 1 = 2 = Automotive Catalogue Handling J-Series
RkJQdWJsaXNoZXIy NzYzOTY1