CAT24-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Solenoid valves manifold 1 | 6 Series PX - Serial systems ►CANopen® protocol node kit Current limitations Scheme / Overall dimensions and I/O layout PIN 1 CAN_SHLD Optional CAN Shield 2 CAN_V+ Optional CAN external positive supply (Dedicated for supply of transceiver and Optocouplers, if galvanic isolation of the bus node applies) 3 CAN_GND Ground / 0V / V4 CAN_H CAN_H bus line (dominant high) 5 CAN_L CAN_L bus line (dominant low) 4 1 3 2 3 2 4 5 1 4 1 3 2 5 42 90 28 PIN 1 2 3 0 V 4 A 4 A 4 A 4 - NETWORK connectors DESCRIPTION POWER SUPPLY connector M12A 4P MALE M12A 5P FEMALE M12A 5P MALE SIGNAL DESCRIPTION + 24 V DC (LOGICS & INPUTS) N.C. + 24 V DC (OUTPUTS) MAX. CURRENT Technical characteristics Specifications CiA Draft Standard Proposal 301 V 4.10 (15 August 2006) Case Reinforced technopolymer Power supply Voltage + 24 V DC ± 10% Node only current consumption on + 24 V DC inputs 40 mA Power supply diagnosis Green LED PWR NODE / Green LED PWR OUT Communication Connection 2 M12 5 pins male-female connectors type A (IEC 60947-5-2) Baud rate 10 - 20 - 50 - 125 - 250 - 500 - 800 - 1000 Kbit/s Addresses possible numbers From 1 to 63 Maximum nodes number in network 64 (slave + master) Bus maximum recommended length 100 m at 500 Kbit/s Bus diagnosis Green / red status LED Configuration file Available from our web site http://www.pneumaxspa.com Protection degree IP65 when assembled Temperature °C -5 ... +50 Coding: K5530.64.VCO V VERSION 32 = 32 output bits available for valve connections 48 = 48 output bits available for valve connections CANopen® node manages 64 inputs and outputs. Accessory modules can be connected in whatever order and configuration. Connection to CANopen® fieldbus is made via two M12, male and female, 5 pins, type A circular connectors, in parallel between them; connectors pinout is compliant to CiA Draft recommendation 303-1 (V. 1.3 : 30 December 2004). Transmission speed and address, as well as termination resistor activation are set via DIP-switches. CANopen® node is available in two versions with 32 or 48 outputs allocated to solenoid valves on the manifold directly connected to the node. Such outputs correspond to least significant bytes and their allocation is independent of how many solenoid valves are installed. Remaining outputs can be used to control the modules. Byte allocation to additional modules is fully automatic. Both stand alone and integrated components must operate within the current limits of the fieldbus node; please note: the solenoid valves are supplied by OUTPUTS + 24 V DC (pin 4). To compute the maximum current on the OUTPUTS + 24 V DC, please use the following formula: = number of installed modules = maximum total current absorbed by the i-th module on the OUTPUTS + 24 V DC supply rail (please see specifications of the single module) = number of installed solenoid pilots = mean absorbed current per solenoid pilot (please see table below) Series i_EV 2200 "Optyma S" 36 mA 2500 "Optyma F" 54 mA 2500 "Optyma T" 54 mA Series 2700 24 mA (1 W version) / 100 mA (2,3 W version) For each fieldbus node, maximum deliverable current by OUTPUTS + 24 V DC supply is 4 A, moreover the sum of the currents on OUTPUTS + 24 V DC and INPUTS + 24 V DC must not exceed 4 A. Where: = number of installed modules = maximum total current absorbed by the i-th module on the INPUTS + 24 V DC supply rail (please see specifications of the single module) In case total current is more than 4 A, it is mandatory to supply modules exceeding current limit with power supply module K5030.M12.

RkJQdWJsaXNoZXIy NzYzOTY1