Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Solenoid valves manifold 1 | 32 Series 3000 EVO - STAND ALONE (15,5 mm) ►Solenoid-Solenoid 2x3/2 (External feeding) 25 35 14.5 100.9 15.5 36 Ø3.2 5 1 G1/8” G1/8” 3 G1/8” M8x1 - 6g G1/8” G1/8” 4 2 M5 12 M5 14 L14 L12 C= 82 9.8 C= 02 4 = + 24 V DC 3 = GND M8 L12 = Manual over ride - side 12 L14 = Manual over ride - side 14 1 = N.C. Coding: 3415.62.F.25.C F FUNCTION 44 = N.C.-N.C. (5/3 Open centres) 45 = N.C.-N.O. 54 = N.O.-N.C. 55 = N.O.-N.O. (5/3 Pressured centres) C ELECTRICAL CONNECTION 02 = H 90° SPEED-UP connector + 24 V DC 82 = M8 SPEED-UP connector + 24 V DC Weight 100 g SHORT FUNCTION CODE: N.C.-N.C. (5/3 Open centres)= “F” N.O.-N.O. (5/3 Pressured centres)= “G” N.C.-N.O.= “H” N.O.-N.C.= “I” 2 3 1 14 5 4 12 2 3 1 14 5 4 12 2 3 1 14 5 4 12 2 3 1 14 5 4 12 Technical characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Flow rate at 6 bar with Δp=1 (Nl/min) 500 Responce time according to ISO 12238, activation time (ms) 10 Responce time according to ISO 12238, deactivation time (ms) 15 Working pressure (bar) From vacuum to 10 Pilot pressure (bar) ≥3+(02 x Inlet pressure) Temperature °C -5 ... +50