CAT25-EN

163 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Function fittings Series IPC Pneumatic fittings Valves and function fittings Function fittings Series IPC Technical sheet FLUID Air (no other gases or liquids) OPERATION PRESSURE 0,05-1,0Mpa (150psi) NEGATIVE PRESSURE Please contact technical Dept. OPERATING TEMPERATURE 0-60 °C (32-140 °F) APPLICABLE TUBE Polyurethane and Nylon Control method AIR FLOW METER IN METER OUT (B) AIR FLOW Thread to tube Tube to thread PCVC PCVF Structure chart Features Allow the airflow in one direction but stops in the opposite direction. Applications Check valves allow airflow in one direction Notes Tight the thread according to the rule. It won’t work if too tight. O-Ring (NBR) Packing (NBR) Valve Back ring (POM) Collar Nylon tube Polyurethane tube Sleeve (POM) Lock ciaws (SUS) Valve spring Body (Brass) Hold Pneumatic symbol Ordering code MODEL TYPE IPCVC = Straight male tapered unidirectional fitting IPCVC-G = Straight male parallel unidirectional fitting IPCVF = Tapered male/female unidirectional fitting IPCVF-G = Parallel male/female unidirectional fitting IPCVU = Unidirectional straight connector TUBE CONNECTION 4 ... 12 = Tube diameter Ø 4; 6; 8; 10; 12 mm THREADED CONNECTION 01 = R1/8” Tapered thread 02 = R1/4” Tapered thread 03 = R3/8” Tapered thread 04 = R1/2” Tapered thread G01 = G1/8” Parallel thread G02 = G1/4” Parallel thread G03 = G3/8” Parallel thread G04 = G1/2” Parallel thread FLOW RATE DIRECTION BLANK = from thread to tube B = from tube to thread IPCVC 04 G04 B

RkJQdWJsaXNoZXIy NzYzOTY1