CAT25-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 71 Pneumatic fittings Stainless steel push-in fittings Series SS FLUIDS Compressed air, water, steam (for different fluid please contact our Technical Dept.) APPLICATIONS Pneumatic equipments which are applied widely in the range of Industy such as food service industry, chemical industry and medical industry. In general where required to ensure anti-corrosion and acid resistant, or usage at high temperature. SUGGESTED TUBES TPU (Polyurethane), PA11/PA12 (Polyamide), TPE (Polyethilene), TPA (Polyurethane/Copolyester) TUBES TOLERANCES Diam. between 4 and 10 mm +/- 0,05 Diam. from 12 mm +/- 0,1 RECOMMENDED LIMIT VALUES Temperature The working temperatures range is between -20°C and +140°C Working pressure The working pressure range is between 0 and 1,5 MPa (0-15 bar) Max. pressure 1,8 MPa (18 bar) Note For more complete informations please read the technical catalogue of your tube supplier. THREAD TYPE BSP paralell UNI-ISO 228; BSP tapered UNI-ISO 7; Metric ISO/R 262 MATERIALS Body, sleeve, collar and back ring Stainless Steel SUS316L Spring Stainless Steel SUS316L Seals FKM/FPM IMPORTANT NOTE The raw material is non-magnetic, however after cold working, a small amount of austenite could be transformed into martensite, which could be very weakly magnetic. Technical sheet Test results to FDA specifications compatibility, made by on behalf of the manufacturer Test report N. Data Period (days) Item Main material Test purpose A TRHZ1208110 06/08/2012 6 Seal ring Viton FPM fluororubber (FKM) The compliance with the food and drug administration regulations for determining the amount of chloroform-soluble extractives (ppm) from closures with sealing gaskets for food containers B TRHZ1208111 06/08/2012 6 Elbow fitting mod SSV Stainless Steel SUS316L To determine total chromium content in the submitted sample C TRHZ1208112 06/08/2012 6 Straight Fitting mod. SSC-G Stainless Steel SUS316L To determine total chromium content in the submitted sample Test method (ref. FDA 21 CFR 177.1210) Test risult Conclusion A Immension for 2 hours in distilled water at 212°F Detected value 13,0 Max permissible 50,0 When tested as specified, the test results of the submitted sample comply with the FDA specifications for determining the amount of chloroform-soluble extractivers for closures (clos) Immension for 2 hours in alcohol 8% at 212°F Detected value 7,0 Max permissible 50,0 Immension for 2 hours in n-heptane at 150°F Detected value 11,5 Max permissible 50,0 B Titration method Detected value 16,38% Max permissible >=10,5% When tested as specified, the test results of the submitted sample is suitable for contact with food C Titration method Detected value 17,18% Max permissible >=10,5% When tested as specified, the test results of the submitted sample is suitable for contact with food Push-in fittings

RkJQdWJsaXNoZXIy NzYzOTY1