CATGEN-EN 2025

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution 1 | 118 Spool type valves and solenoid valves Series T400 - G1/4" ►Solenoid-Spring (Self feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1050 Orifice size (mm) 8.5 Working ports size G 1/4" Weight 205 g Minimum pilot pressure 2,5 bar T424.32.0.1.V Weight 235 g Minimum pilot pressure 2,5 bar T424.52.0.1.V Coding: T424.T.0.1.V T TYPE 32 = 3 ways, 2 positions 52 = 5 ways, 2 positions V VOLTAGE B04 = 12 V DC B05 = 24 V DC B09 = 24 V DC (2 W) B56 = 24 V 50-60 Hz B57 = 110 V 50-60 Hz B58 = 230 V 50-60 Hz 2 1 3 2 1 3 4 5 ►Solenoid-Spring (External feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1050 Orifice size (mm) 8.5 Working ports size G 1/4" Pilot ports size G 1/8" Weight 205 g Minimum pilot pressure 2,5 bar T424.32.0.1.E.V Weight 235 g Minimum pilot pressure 2,5 bar T424.52.0.1.E.V Coding: T424.T.0.1.E.V T TYPE 32 = 3 ways, 2 positions 52 = 5 ways, 2 positions V VOLTAGE B04 = 12 V DC B05 = 24 V DC B09 = 24 V DC (2 W) B56 = 24 V 50-60 Hz B57 = 110 V 50-60 Hz B58 = 230 V 50-60 Hz 2 1 3 12 2 1 3 4 5 14

RkJQdWJsaXNoZXIy NzYzOTY1