Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool type valves and solenoid valves 1 | 129 Series 2100 - Size 10mm FLAT ►Solenoid - Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 7 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 150 Orifice size (mm) 2.5 Working ports size M5 Weight 38 g Minimum pilot pressure 2 bar M2 11,8 27 79 83,5 17,25 29,75 47 45,5 8,4 4 M5 10,5 25,5 Coding: 2135.52.00.39.T T VOLTAGE 01 = + 12 V DC 90° conn. with LED 21 = + 12 V DC line conn. with LED 02 = + 24 V DC 90° conn. with LED 22 = + 24 V DC line conn. with LED 11 = + 12 V DC 90° conn. with LED downward 31 = + 12 V DC line conn. with LED downward 12 = + 24 V DC 90° conn. with LED downward 32 = + 24 V DC line conn. with LED downward 91 = + 12 V DC for integral electrical connections downward 92 = + 24 V DC for integral electrical connections downward 2 1 3 4 5 ►Solenoid - Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 7 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 150 Orifice size (mm) 2.5 Working ports size M5 Weight 38 g Minimum pilot pressure 2 bar M2 11,8 27 79 83,5 17,25 29,75 47 45,5 8,4 4 M5 10,5 25,5 Coding: 2135.52.00.36.T T VOLTAGE 01 = + 12 V DC 90° conn. with LED 21 = + 12 V DC line conn. with LED 02 = + 24 V DC 90° conn. with LED 22 = + 24 V DC line conn. with LED 11 = + 12 V DC 90° conn. with LED downward 31 = + 12 V DC line conn. with LED downward 12 = + 24 V DC 90° conn. with LED downward 32 = + 24 V DC line conn. with LED downward 91 = + 12 V DC for integral electrical connections downward 92 = + 24 V DC for integral electrical connections downward 2 1 3 4 5 ►Solenoid - Solenoid Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 7 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 150 Orifice size (mm) 2.5 Working ports size M5 Weight 50 g Minimum pilot pressure 1,5 bar M2 M5 11,8 24,25 47 45,5 4 27 96 105,5 66,5 10,5 28 19,75 8,4 Coding: 2135.52.00.35.T T VOLTAGE 01 = + 12 V DC 90° conn. with LED 21 = + 12 V DC line conn. with LED 02 = + 24 V DC 90° conn. with LED 22 = + 24 V DC line conn. with LED 11 = + 12 V DC 90° conn. with LED downward 31 = + 12 V DC line conn. with LED downward 12 = + 24 V DC 90° conn. with LED downward 32 = + 24 V DC line conn. with LED downward 91 = + 12 V DC for integral electrical connections downward 92 = + 24 V DC for integral electrical connections downward 2 1 3 4 5
RkJQdWJsaXNoZXIy NzYzOTY1