CATGEN-EN 2025

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Direct operated solenoid valves 1 | 176 Series 300 - Size 10 mm 3 1 2 3 1 2 1 2 3 1 2 Functional schematics for standard version 1 = SUPPLY PORT 2 = OUTLET PORT 3 = EXHAUST PORT Normally Closed (N.C.) 3/2 Normally Closed (N.C.) 2/2 Normaly Open (N.O.) 3/2 AT REST AT REST AT REST ACTUATED ACTUATED ACTUATED Functional schematics for Speed-up version Normally Closed (N.C.) 3/2 1 = SUPPLY PORT 2 = OUTLET PORT 3 = EXHAUST PORT AT REST ACTUATED This series of directly operated vales is characterized by its reduced dimensions. They are designed to be mounted individually or on manifold. The high operating speed and high flow rate in consideration of the reduced dimensions, in combination with the high compatibility of the material used to manufacture them ensure a high variety of possible application fields. All valves have manual override as standard and are available in 3/2 configuration N.O. and N.C. as well as 2/2 N.C. both 12 or 24 V DC or AC. Electrical connection can be via co moulded cables or via connector, in this configuration a LED indicates the coil status. Ensure that the fixing screws are tightened with 0.15Nm maximum. The 10mm Speed-up version are built in accordance to the ISO 15218-2003 standard with a flow rate of 24Nl/min. The coil integrates a dedicated circuit board which enables to contain the power consumption to 0.35W in case of the high flow rate version and to 0.1W in case of the standard flow rate version. Construction characteristics: Electrical part: Miniature solenoid consisting of a coil made of copper wire of different diameters depending on voltage,isolated according to "F" class standard, with injection-moulded nylon-glass application. All parts forming the cladding, the electrical connections and the pole pieces are protected against corrosion. Mechanical part: Stainless steel 430F armatures FPM poppets body in thermoplastic material and manual override and plug in nickel plated brass. Valves must be mounted on single or multiple manifold to be used. Pneumatic Electric 0 ... 7 bar 0,7 mm 1,1 mm -5° ... +50°C 14 Nl/min 24 Nl/min 22 NI/min 29 Nl/min 50 million 5:4:4 12 ... 24 Volt D.C. 1,3 Watt 0,35 Watt (1) -5% ... +10% 8 ms 10 ms F (155°C) IP65 (with cables) IP40 (with connectors) IP00 (with Faston) Protection degree Working pressure Orifice size Temperature Flow rate at 6 bar with ∆p=1 bar Exhaust flow rate Life expectancy, number of cycles per minute Voltages Power Voltage tollerance Response time when energized * Response time when de-energized * Copper wire isolation class Standard Version Speed-Up Version (1) = consumption wrapping in opening phase 3, 5W (10 ms), consumption wrapping in maintenance phase 0.35 W. (*) "Response time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001, Pneumatic fluid power - Directional control valves - Measurement of shifting time" Technical characteristics 2 1 2 1 2 3 1 2 3 1 2 1 3 2 1 3 1 2 3 1 2 3 Compressed air, purity class according to ISO 8573-1:2010

RkJQdWJsaXNoZXIy NzYzOTY1