Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Series SA Magnetic sensors 3 Pneumatic actuation 3 | 255 REED style versions, with 2m cable 27 12 14,5 27 15,5 14,5 Ordering code brown blue LOAD ~ ~ Type - AC * brown blue LOAD Type - U * brown blue LOAD Type U/1 * LOAD blue brown Type - DC * ~ ~ ~ ~ Slot detail type “A” 12 16.2 5.5 2.5 ► 2 Sensors with 2 wires cable (PUR Ø4,2 mm 2x0,34 mm ) The load (LOAD) can be connected either to negative or positive pole. * These sensors can be used on cylinders series: Diagrams and connections SERIES DESCRIPTION MOUNTED 1319 - 1320 1500 Compact cylinders "Europe" (from Ø32) directly on groove 1605 Rodless cylinders with brackets code 1600.A 1200 1390 - 1391 with brackets code 1390.D for cylinders ECOLIGHT Ø50 and Ø63 for cylinders ECOLIGHT Ø80 and Ø100 for microbore with threaded end covers and “TECNO-MIR” microbore for microbore "MIR" with rolled end covers, cylinders from Ø16 to Ø32 for microbore "MIR-INOX" with rolled end covers for cylinders from Ø32 to Ø63 for cylinders from Ø80 to Ø125 for cylinders from Ø160 to Ø200 for cylinders Ø250 and Ø320 (ISO) for cylinders Ø32 and Ø40 for cylinders Ø50 and Ø63 for cylinders Ø80 and Ø100 for cylinders Ø125 for cylinders ECOLIGHT Ø32 and Ø40 for cylinders Ø200 for cylinders Ø160 for cylinders ECOLIGHT Ø125 - Ø200 with brackets code 1320.F with brackets code 1390.B with brackets code 1390.C with clamps code 1260.Ø.F with clamps code 1280.Ø.F with clamps code 1280.Ø.FX with brackets code 1306.A with brackets code 1306.B with brackets code 1306.C with brackets code 1306.D with brackets code 1320.A with brackets code 1320.B with brackets code 1320.C with brackets code 1320.D with brackets code 1320.E with brackets code 1390.A 1306 - 1307 - 1308 1315 1,2A 1,5A 12 - 30V 32W 1,5A 6A 12 - 230V 375VA 3 - 230V 20VA 12 - 48V 15W 0 - 230V 10VA 0 - 48V 8W 3V max 2V max 3V max 2x0,34 mm² Ø4,2 mm PUR IP 65 2 ms 1 ms 10 cicles ± 0,1 mm N.O. -20° C - 70°C 0V 0,5A 1A 0,3A 0,8A a.c. U U/1 D.C. A.C. d.c. Technical characteristics 7 Cable section Maximum permanent current Maximum current (pulses of 0,5 sec.) Voltage range Maximum permanent power Working temperature Maximum voltage drop Degree of protection Connecting time Disconnecting time Average working period Repetition of intervention point Type of contact a.c. d.c. 1600.U/1 universal sensor without led (REED ampulla only) Cylinders and microbore cylinders 1500.AC sensor for alternating current with led 1500.DC sensor for continuous current with led 1500. U universal sensor with led 1500.U/1 universal sensor without led (REED ampulla only) Rodless cylinders 1600.AC sensor for alternating current with led 1600.DC sensor for continuous current with led 1600.U universal sensor with led
RkJQdWJsaXNoZXIy NzYzOTY1