CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 95 Series 400 ►Solenoid - Solenoid 5 ways 3 connections Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 410 Orifice size (mm) 6 Working ports size G 1/8" Responce time according to ISO 12238, activation time (ms) 23,0 (closed centres) 21,5 (open centres) 18,9 (pressured centres) Responce time according to ISO 12238, deactivation time (ms) 41,0 (closed centres) 38,0 (open centres) 40,2 (pressured centres) Coding: 488.53.F.0.0.S F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 S SOLENOID M11 = 24V D.C. (rating power 3,8W) M56 = 24V 50/60Hz (starting power 9VA, rating power 6VA) M57 = 110 V 50/60Hz (starting power 9 A, rating power 6 A) M58 = 230V 50/60Hz (starting power 9VA, rating power 6VA) Weight 400 g Minimum working pressure 3 bar 488.53.31.0.0.S Weight 400 g Minimum working pressure 3 bar 488.53.32.0.0.S Weight 400 g Minimum working pressure 3 bar 488.53.33.0.0.S

RkJQdWJsaXNoZXIy NzYzOTY1