CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 113 Series T400 ►Solenoid - Differential (Self-feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 620 Orifice size (mm) 6 Working ports size G 1/8" Responce time according to ISO 12238, activation time (ms) 31,1 (3 ways) 27,9 (5 ways) Responce time according to ISO 12238, deactivation time (ms) 35,0 (3 ways) 34,5 (5 ways) Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Weight 160 g Minimum working pressure 2,5 bar T488.32.0.12.V 5 32 3.2 19 25 G1/8" 83 53 4.2 4.5 26 35 18 20 4.2 4.2 Weight 190 g Minimum working pressure 2,5 bar T488.52.0.12.V 36 38 4.2 4.2 26 4.5 35 18 4.2 27 19 100 25 3.25  G1/8" 53 Coding: T488.T.0.12.V T TYPE 32 = 3 ways 52 = 5 ways V VOLTAGE M9 = Solenoid - Spring (Self-feeding) M11 = 24V D.C. (rating power 3,8W) M56 = 24V 50/60Hz (starting power 9VA, rating power 6VA) M57 = 110 V 50/60Hz (starting power 9VA, rating power 6VA) M58 = 230V 50/60Hz (starting power 9VA, rating power 6VA) ►Solenoid - Differential (External-feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 620 Orifice size (mm) 6 Working ports size G 1/8" Responce time according to ISO 12238, activation time (ms) 31,1 (3 ways) 27,9 (5 ways) Responce time according to ISO 12238, deactivation time (ms) 35,0 (3 ways) 34,5 (5 ways) Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Weight 160 g Minimum working pressure 2,5 bar T488.32.0.12E.V 5 32 3.2 19 25 M5 M5 G1/8" 83 53 26 4.5 35 4.2 4.2 4.2 18 20 Weight 190 g Minimum working pressure 2,5 bar T488.52.0.12E.V                    Coding: T488.T.0.12E.V T TYPE 32 = 3 ways 52 = 5 ways V VOLTAGE M9 = Solenoid - Spring (Self-feeding) M11 = 24V D.C. (rating power 3,8W) M56 = 24V 50/60Hz (starting power 9VA, rating power 6VA) M57 = 110 V 50/60Hz (starting power 9VA, rating power 6VA) M58 = 230V 50/60Hz (starting power 9VA, rating power 6VA)

RkJQdWJsaXNoZXIy NzYzOTY1