Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 120 Series T400 - Accessories ►Solenoid - Solenoid (Self-feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 900 Orifice size (mm) 8.5 Working ports size G 1/4" Weight 295 g Minimum piloting pressure 3 bar Coding: T424.53.F.0.0.V F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres V VOLTAGE B04 = 12 V DC B05 = 24 V DC B09 = 24 V DC (2 W) B56 = 24 V 50-60 Hz B57 = 110 V 50-60 Hz B58 = 230 V 50-60 Hz ►Solenoid - Solenoid (External-feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 900 Orifice size (mm) 8.5 Working ports size G 1/4" Pilot ports size G 1/8" Weight 295 g Minimum piloting pressure 3 bar Coding: T424.53.F.0.0.E.V F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres V VOLTAGE B04 = 12 V DC B05 = 24 V DC B09 = 24 V DC (2 W) B56 = 24 V 50-60 Hz B57 = 110 V 50-60 Hz B58 = 230 V 50-60 Hz