CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 155 Series 2400 - Size 18mm VDMA ►Pneumatic - Pneumatic 5 ways 3 connections Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Maximum piloting pressure (bar) 3 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 550 Orifice size (mm) 5 Weight 165 g Coding: 244C.53.F.18 C TYPE ELECTROPILOT EXHAUST 1 = on base (only for self feeding valves) 5 = on pilot (for all version) F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres ►Solenoid - Solenoid 5 ways 3 connections Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Maximum piloting pressure (bar) 3 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 550 Orifice size (mm) 5 Weight 235 g Coding: 244C.53.F.V.T C TYPE ELECTROPILOT EXHAUST 1 = on base (only for self feeding valves) 5 = on pilot (for all version) F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres V VERSION 24 = Solenoid external-Solenoid external 35 = Solenoid-Solenoid T VOLTAGE 01 = 12V DC 02 = 24V DC 05 = 24V AC 06 = 110V AC 07 = 230 V AC 08 = 24V DC 1W 09 = 24V DC downward 11 = 12V DC downward 12 = 24V DC downward 15 = 24V AC downward 16 = 110V AC downward 17 = 230 V AC downward 18 = 24V DC 1W downward 19 = 24V DC Earth faston downward