CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 2 Series 104 - Mechanical and manual command ►Tappet - Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +70 Flow rate at 6 bar with Δp=1 (Nl/min) 90 Orifice size (mm) 2.5 Working ports size ø4 tube Coding: 104.T.0.1.W.F T TYPE 22 = 2 ways 32 = 3 ways W CONNECTION TYPE L = Lateral P = Rear F FUNCTION A = Normally Open C = Normally Closed 2/2 - 3/2 - Lateral connections Weight 20 g Operating force 13 N 104.T.0.1.L.F 1 2 2/2 - 3/2 - Rear connections Weight 20 g Operating force 13 N 104.T.0.1.P.F 1 2 1 2 ►Push button - Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +70 Flow rate at 6 bar with Δp=1 (Nl/min) 90 Orifice size (mm) 2.5 Working ports size ø4 tube Coding: 104.T.6.22/C.W.F T TYPE 22 = 2 ways 32 = 3 ways 52 = 5 ways C BUTTON COLOR 1 = Red 2 = Black 3 = Green 4 = Yellow W CONNECTION TYPE L = Lateral P = Rear F FUNCTION (only for 2 or 3 ways) A = Normally Open C = Normally Closed 2/2 - 3/2 - Lateral connections Weight 50 g Operating force 18 N 104.T.6.22/C.L.F 2/2 - 3/2 - Rear connections Weight 50 g Operating force 18 N 104.T.6.22/C.P.F 5/2 - Lateral connections Weight 105 g Operating force 30 N 104.52.6.22/C.L 5/2 - Rear connections Weight 105 g Operating force 30 N 104.52.6.22/C.P

RkJQdWJsaXNoZXIy NzYzOTY1