Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Valves and solenoid valves poppet system 1 | 214 Series 700 - For vacuum - G3/4" ►Pneumatic - Spring Operational characteristics Fluid Vacuum Minimum piloting pressure (bar) 2 Temperature °C -5 ÷ +70 Orifice size (mm) 20 Working ports size G3/4" Pilot ports size G1/8" Weight 990 g 97 22,5 55,5 Ø6,5 G1/8 Ø75 G3/4 Ø55 Ø63 G3/4 Coding: 773/V.32.11.F F FUNCTION 1C = Normally Closed 1A = Normally Open For vacuum - N.O. Outlet port 1 Outlet port 2 Pump 3 For vacuum - N.C. Exhaust port 3 Outlet port 2 Pump 1 ►Solenoid-Spring - Internal pilot Operational characteristics Fluid Vacuum Temperature °C -5 ÷ +50 Orifice size (mm) 20 Working ports size G3/4" Pilot ports size G1/8" Weight 1050 g 151 97 54 22,5 55,5 Ø6,5 Ø75 G3/4 Ø55 Ø63 G3/4 Coding: 773/V.32.0.F.M2/V F FUNCTION 1AA = Normally Open 1AC = Normally Closed For vacuum - N.O. Exhaust port 3 Outlet port 2 Pump 1 For vacuum - N.C. Outlet port 1 Outlet port 2 Pump 3 ►Solenoid-Spring - External pilot Operational characteristics Fluid Vacuum Minimum piloting pressure (bar) 2 Temperature °C -5 ÷ +50 Orifice size (mm) 20 Working ports size G3/4" Pilot ports size G1/8" Weight 1050 g 151 97 54 22,5 55,5 Ø6,5 G1/8 Ø75 G3/4 Ø55 Ø63 G3/4 Coding: 773/V.32.0.F.M2 F FUNCTION 1A = Normally Open 1C = Normally Closed For vacuum - N.O. Outlet port 1 Outlet port 2 Pump 3 For vacuum - N.C. Exhaust port 3 Outlet port 2 Pump 1