CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Valves and solenoid valves poppet system 1 | 218 Series 700 - For compressed air - G1 1/2" ►Solenoid - Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Minimum piloting pressure (bar) 2,5 (External pilot version) 3 (Internal pilo version) Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 33500 Orifice size (mm) 38 Working ports size G1 1/2" Pilot ports size G1/8" Weight 4450 g 238 86 115 G1 ½ Ø10,5 135 110 95 2A 3R 1P G1/8 Ø74 160 Coding: 776.32.0.F.S F FUNCTION 1AC = Internal pilot normally closed 1C = External pilot normally closed S SOLENOID CODE SEE SOLENOID VALVES "S" TYPE, SERIES 300 Internal pilot - N.C. Inlet port 1 Outlet port 2 Exhaust port 3 External pilot - N.C. Inlet port 1 Outlet port 2 Exhaust port 3