Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution ISO 5599-1 Valves and solenoid valves 1 | 284 Series 1000 M12 - Size 2 ►Solenoid-Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 2.5 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1600 Response time according to ISO 12238, activation time (ms) 24 Response time according to ISO 12238, deactivation time (ms) 124 Weight 510 g 70,5 48 38 Ø6,5 52 24 152 M12x1 Coding: 1112.52.3.9.T T VOLTAGE 12P = 24VDC 2 1 3 4 5 ►Solenoid-Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 2 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1600 Response time according to ISO 12238, activation time (ms) 37 Response time according to ISO 12238, deactivation time (ms) 90 Weight 515 g 70,5 48 38 Ø6,5 52 24 152 M12x1 Coding: 1112.52.3.6.T T VOLTAGE 12P = 24VDC 2 1 3 4 5
RkJQdWJsaXNoZXIy NzYzOTY1