Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice “NAMUR” valves and solenoid valves Series 514 1 | 296 1 Air distribution ►Universal kit Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C Standard valves (-10 ... +50) Low temperature valves (-30 ... +50) ATEX valves (-20 ... +40) Flow rate at 6 bar with Δp=1 (Nl/min) 1100 Orifice size (mm) 8 Working ports size G 1/4" Coding: M514.92.00.V.TO M MODEL = Standard valve X = ATEX valve V VERSION 16 = Pneumatic - Differential 18 = Pneumatic - Pneumatic 19 = Pneumatic - Spring 35 = Solenoid - Solenoid 36 = Solenoid - Differential 39 = Solenoid - Spring T VOLTAGE B04 = 12 VDC B05 = 24 VDC B09 = 24 VDC (2W) B56 = 24V (50-60 Hz) B57 = 110V (50-60 Hz) B58 = 230 V (50-60 Hz) C04 = 12 VDC C05 = 24 VDC C09 = 24 VDC (2W) C56 = 24 V (50-60 Hz) C57 = 110 V (50-60 Hz) C58 = 230 V (50-60 Hz) F04 = 12 VDC F05 = 24 VDC F56 = 24 V (50-60 Hz) F57 = 110 V (50-60 Hz) F58 = 230 V (50-60 Hz) O TEMPERATURE OPTIONS = Standard valves (-10 ... +50) LT = Low temperature valves (-30 ... +50) = ATEX valves (-20 ... +40) Minimum pilot pressure 2,5 bar Maximum fitting torque 9 N/m “LT” and “ATEX” versions are not available with MF coils To change a 5/2 valve into a 4/2: Simply replace the bottom plate with the one included in the universal kit (cod. 514.92....) and by plugging port 5 Weight 405 g