CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution ISO 5599-1 valves and solenoid valves 1 | 313 Series 1000 - Valves 5/2-5/3 - Size 3 ►Pneumatic - Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 60 48 66 32 196 64 Ø8,5 Coding: 1013.52.1.9 Weight 1000 g Minimum piloting pressure 2,5 bar ►Pneumatic - Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 60 48 66 32 196 64 Ø8,5 Coding: 1013.52.1.6 Weight 1020 g Minimum piloting pressure 2 bar ►Pneumatic-Pneumatic 5/2 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 60 48 66 32 196 64 Ø8,5 Coding: 1013.52.1.8 Weight 1050 g Minimum piloting pressure 1,5 bar ►Pneumatic-Pneumatic 5/3 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3000 60 48 66 32 196 64 Ø8,5 Coding: 1013.53.F.1.8 F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres Weight 1050 g Minimum piloting pressure 3 bar 1013.53.F.1.8