CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution ISO 5599-1 valves and solenoid valves 1 | 326 Series 1000 M12 - Size 3 ►Solenoid-Solenoid 5/2 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Minimum piloting pressure (bar) 1.5 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 Responce time according to ISO 12238, activation time (ms) 32 Responce time according to ISO 12238, deactivation time (ms) 37 Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Weight 1370 g 66 196 32 64 48 87,5 M12x1 Ø8,5 Coding: 1113.52.3.5.T T COIL VOLTAGE 12P = 24VDC ►Solenoid-Solenoid 5/3 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Minimum piloting pressure (bar) 3 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 Responce time according to ISO 12238, activation time (ms) 30 (Closed centres) 30 (Open centres) 32 (Pressured centres) Responce time according to ISO 12238, deactivation time (ms) 305 (Closed centres) 230 (Open centres) 270 (Pressured centres) Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Weight 1380 g 66 196 32 64 48 87,5 M12x1 Ø8,5 Coding: 1113.53.F.3.5.T T COIL VOLTAGE 12P = 24VDC

RkJQdWJsaXNoZXIy NzYzOTY1