CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Solenoid valves manifold ISO 15407-2 Series 2700 1 Air distribution 1 | 375 ►Solenoid-Solenoid 5/3 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Minimum piloting pressure (bar) 3 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 660 Responce time according to ISO 12238, activation time (ms) 12 Responce time according to ISO 12238, deactivation time (ms) 60 Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Weight 310 g The "Activations time" values, are valid only for the 2,3W versions 60 47 1,5 5 19 Ø3,2 M4 26,5 9,5 8,5 58 136 68 7,35 24 9,5 Coding: 2741.53.31.P.T P PILOTING 35 = Self feeding 24 = External feeding T VOLTAGE 01 = 12V DC 02 = 24V DC 08 = 24V DC 1 Watt SHORT FUNCTION (Self feeding) "EA" SHORT FUNCTION (External feeding) "EE" 5 14 4 13 2 12 ►Solenoid-Solenoid 2x3/2 (Self feeding / External feeding) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Minimum piloting pressure (bar) ≥2+(0,3xP.alim.) Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 550 Responce time according to ISO 12238, activation time (ms) 15 (Self feeding) 12 (External feeding) Responce time according to ISO 12238, deactivation time (ms) 15 (Self feeding) 60 (External feeding) Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Weight 310 g The "Activations time" values, are valid only for the 2,3W versions “Example: If inlet pressure is set at 5bar then pilot pressure must be at least Pp=2+(0.3*5)=3,5bar” 60 47 1,5 5 19 Ø3,2 M4 26,5 9,5 8,5 58 136 68 7,35 24 9,5 Coding: 2741.62.F.P.T F FUNCTION 44 = 2 Coils 3/2 NC 45 = 1 Coil 3/2 NC (14) + 1 Coil 3/2 NO (12) 55 = 2 Coils 3/2 NO 54 = 1 Coil 3/2 NO (14) + 1 Coil 3/2 NC (12) P PILOTING 35 = Self feeding 24 = External feeding T VOLTAGE 01 = 12V DC 02 = 24V DC 08 = 24V DC 1 Watt SHORT FUNCTION (Self feeding): 2 3/2 NC="FA" 1 3/2 NC (14) + 1 3/2 NA (12)="HA" 2 3/2 NA="GA" 1 3/2 NA (14) + 1 3/2 NC (12)="IA" SHORT FUNCTION (External feeding): 2 3/2 NC="FE" 1 3/2 NC (14) + 1 3/2 NA (12)="HE" 2 3/2 NA="GE" 1 3/2 NA (14) + 1 3/2 NC (12)="IE" 5 14 4 1 3 2 12 5 14 4 1 3 2 12 5 14 4 1 3 2 12 5 14 4 1 3 2 12 5 14 4 1 3 2 12

RkJQdWJsaXNoZXIy NzYzOTY1