CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice CAnopen® Module 1 Air distribution Solenoid valves manifold Series 2300 - ENOVA® - Serial Systems 1 | 415 5523.22 MAX 22 OUT 90 32.5 50 60 Ordering code General: ® CANopen module is directly integrated on Enova solenoid valves manifold via a 25 poles connector, normally used for multipolar cable connection. Enova solenoid valves connected to node must be PNP equivalent (final 02 in ordering code). The node can be easily installed also on solenoid valves manifold already mounted on equipment. Module can manage up to 22 solenoid valves, and, in the same time, a max number of 3 Input modules 5200.08. ® CANopen module recognizes automatically the presence of the Input modules on power on. Regardless of the number of Input modules connected, the managable solenoid valves are 22. Node power supply is made by a M12 4P male circular connector. The separation between node 24 VDC Power supply and outputs 24 VDC allows to switch off the outputs maintaning powered the node and inputs, if present. ® Connection to Bus CANopen is possible via 2 M12 5P male - female circular connectors; these two are connected in parallel and according to CiA Draft Standard Proposal 301 V 4.10 (15 August 2006). Transmission speed can be set by 3 dip-switches. The node address can be set by 6 dip-switches using BCD numeration. The module includes an internal terminating resistance that can be activated by a dip-switch. Scheme / Overall dimensions and I/O layout : Technical characteristics Model Specifications Case Power supply connection Power supply voltage Node consumption (without inputs) Power supply diagnosis PNP equivalent outputs Maximum current for output Maximum output number Max output simultaneously actuated Network connectors Baud rate Addresses, possibile numbers Max nodes in net Bus maximum recommended length Bus diagnosis Configuration file IP protection grade Temperature range 5523.22 CiA Draft Standard Proposal 301 V 4.10 (15 August 2006) Reinforced technopolymer M12 4P male connector (IEC 60947-5-2) +24 VDC +/- 10% 25 mA Green led PWR +24 VDC +/- 10% 100 mA 22 22 2 M12 5P connectors male-female (IEC 60947-5-2) 10 - 20 - 50 - 125 - 250 - 500 - 800 - 1000 Kbit/s From 1 to 63 64 (slave + master) 100 m a 500 Kbit/s Green led + Red led Available from our web site: http://www.pneumaxspa.com IP65 when assembled From -0° to +50° C Power supply Outputs Network 2 1 4 3 5 1 2 5 4 3 2 1 3 4 M12 5P MALE NETWORK connectors M12 5P FEMALE POWER SUPPLY connector M12 4P MALE PIN DESCRIPTION 1 2 NC 3 GND 4 +24 VDC (OUTPUTS) +24 VDC (NODE & INPUTS) Optional CAN external positive supply (Dedicated for supply of transceiver and Optocouplers, PIN SIGNAL DESCRIPTION 1 CAN_SHLD Optional CAN Shield 2 CAN_V+ 3 CAN_GND Ground / 0V / V4 CAN_H CAN_H bus line (dominant high) 5 CAN_L CAN_L bus line (dominant low) if galvanic isolation of the bus node applies)

RkJQdWJsaXNoZXIy NzYzOTY1