Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice PROFIBUS DP Module 1 Air distribution 1 | 417 Solenoid valves manifold Series 2300 - ENOVA® - Serial Systems 5323.22 MAX 22 OUT 90 32.5 50 60 Ordering code General: PROFIBUS DP module is directly integrated on Enova solenoid valves manifold via a 25 poles connector, normally used for multipolar cable connection. Enova solenoid valves connected to node must be PNP equivalent (final 02 in ordering code). The node can be easily installed also on solenoid valves manifold already mounted on equipment. Module can manage up to 22 solenoid valves, when is connected 0 or 1 INPUT modules, or 16 if node is fitted with 2 INPUT modules. The max number of INPUT modules 5200.08, is 2 . PROFIBUS DP module recognizes automatically the presence of the Input modules on power on. Node power supply is made by a M12 4P male circular connector. The separation between node 24 VDC Power supply and outputs 24 VDC allows to switch off the outputs maintaning powered the node and inputs, if present. Connection to Bus PROFIBUS DP is possible via 2 M12 type B 5P male - female circular connectors; these two are connected in parallel and according to PROFIBUS Interconnection Technology (Version 1.1 : August 2001). The node address can be set using BCD numeration: 4 dip-switches for the units and 4 dipswitches for the tens. The module includes an internal terminating resistance that can be activated by a dip-switch. Technical characteristics 5323.22 PROFIBUS DP Reinforced technopolymer M12 4P male connector (IEC 60947-5-2) +24 VDC +/- 10% 50 mA Green led PWR +24 VDC +/- 10% 100 mA 22 or 16 if node is fitted with 2 INPUT modules 22 2 M12 5P connectors male-female (IEC 60947-5-2) 125 - 250 - 500 Kbit/s From 1 to 63 64 (slave + master) 100 m a 500 Kbit/s Green led + Red led Available from our web site: http://www.pneumaxspa.com IP65 when assembled From -0° to +50° C Power supply Outputs Network Scheme / Overall dimensions and I/O layout : 2 1 3 4 POWER SUPPLY connector M12 4P MALE 2 1 4 3 5 1 2 5 4 3 Receive / Transmit data -N, A-line PIN SIGNAL DESCRIPTION 1 VP Power supply plus, (P5V) 2 A-line 3 DGND Data Ground (reference potential to VP) 4 B-line Receive / Transmit data -plus, B-line 5 SHIELD Shield or PE NETWORK connectors M12 5P MALE M12 5P FEMALE Model Specifications Case Power supply connection Power supply voltage Node consumption (without inputs) Power supply diagnosis PNP equivalent outputs Maximum current for output Maximum output number Max output simultaneously actuated Network connectors Baud rate Addresses, possibile numbers Max nodes in net Bus maximum recommended length Bus diagnosis Configuration file IP protection grade Temperature range PIN DESCRIPTION 1 2 NC 3 GND 4 +24 VDC (OUTPUTS) +24 VDC (NODE & INPUTS)
RkJQdWJsaXNoZXIy NzYzOTY1