CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 8 Input Module 1 Air distribution 1 | 418 Solenoid valves manifold Series 2300 - ENOVA® - Serial Systems 5200.08 Module 1 60 120 180 Module 1 Module 2 Module 1 Module 2 Module 3 ORANGE LED INPUTS GREEN LED POWER M8 3P FEMALE CONNECTOR General: Modules have 8 connectors M8 3P female. Ordering code Scheme / Overall dimensions and I/O layout : The Inputs are PNP equivalent 24 VDC ±10%. To each connector it is possible to plug both 2 wires Inputs (switches, magnetic switches pressure switches, etc) or 3 wires Inputs (proximity, photocells, electronic sensors, etc). The maximum current available for all 8 Inputs is 200 mA. Each module includes a 200 mA resettable fuse. If a short circuit or a overcharge (overall current >200mA) occur the safety device acts cutting the 24 VDC power supply to all M8 connectors on the module and switching off the green led PWR. Any other Input module connected to the node will remain powered and will function correctly. Once the cause of the fault disappears the green led PWR light up indicating the ON state and the node will re-start to operate. The Maximum number of Input modules supported is 3 for CANopen and DeviceNet, 2 for PROFIBUS DP. ORANGE LED INPUTS 1 4 3 PIN DESCRIPTION 1 +24 VDC 4 INPUT 3 GND