CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Configurator 1 Air distribution Solenoid valves manifold 1 | 435 Series 2200 "OPTYMA-S" Manifold Layout configuration ACCESSORIES W00 = Intermediate supply & exhaust module 0X0 = Diaphragm plug on pipe 1 00Y = Diaphragm plug on pipeE 3 Z00 = Diaphragm plug on pipe 5 0XY = Diaphragm plug on pipe 1 & 3 ZX0 = Diaphragm plug on pipe 5 & 1 Z0Y = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5,1 & 3 VALVES TYPE A = 5/2 Solenoid - Spring B = 5/2 Solenoid - Differential C = 5/2 Solenoid - Solenoid E = 5/3 CC Solenoid - Solenoid F = 2x3/2 NC-NC (= 5/3 OC) Solenoid - Solenoid G = 2x3/2 NO-NO (= 5/3 PC) Solenoid - Solenoid H = 2x3/2 NC-NO Solenoid - Solenoid I = 2x3/2 NO-NC Solenoid - Solenoid T = Free valve space plug __ __ __ __ __ S . . __ LEFT ENDPLATE A2 = 25 poles - Self feeding A3 = 37 poles - Self feeding E2 = 25 poles - External feeding E3 = 37 poles - External feeding ACCESSORIES CONFIGURATION _ _ __ __ MODUL CONFIGURATION Sub-base type Valve type __ MULTIPOINT CONNECTION MP = PNP 24 V DC MN = NPN 24 V DC MA = 24 V AC RIGHT ENDPLATE U0 = Closed U2 = 25 Poles __ __ . __ . . . . I/O MODULE M8 (Requires 25 poles right endplate) SUB-BASE TYPE 3 = 2 Position Monostable sub base ø4 (2 electric signal used) 4 = 2 Position Bistable sub base ø4 (4 electric signals used) 5 = 2 Position Monostable sub base ø6 (2 electric signal used) 6 = 2 Position Bistable sub base ø6 (4 electric signals used) 7 = 2 Position Monostable sub base ø8 (2 electric signal used) 8 = 2 Position Bistable sub base ø8 (4 electric signals used) __ __ __ NOTE: While configuring the manifold always be careful that the maximum number of electrical signals available is 32 The use of monostable valve mounted on a bistable base ( 2 electrical signals occupied for each position) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve without reconfiguring the PLC. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. Well-tried component B10d 50.000.000 Series 2200 OPTYMA-S solenoid valve manifolds managed by multipoint connection are “well tried components” - The product is a well-tried product for a safety-related application according to ISO 13849-1. - The relevant basic and well-tried safety principles according ISO 13849-2 for this product are fulfilled. - The suitability of the product for a precise application must be verified and confirmed by the user. SUB-BASE VARIANTS EMPTY = No variants (SUB-BASE STANDARD) 3 = Diaphragm plug on pipe 1 and 5 4 = Diaphragm plug on pipe 1 and 3 5 = Diaphragm plug on pipe 5 6 = Diaphragm plug on pipe 1, 3 and 5 7 = Diaphragm plug on pipe 1 8 = Diaphragm plug on pipe 3 and 5 9 = Diaphragm plug on pipe 3 __

RkJQdWJsaXNoZXIy NzYzOTY1