Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice PROFIBUS DP Module 1 Air distribution Solenoid valves manifold 1 | 438 Series 2200 "OPTYMA-S" - Serial systems General: 5322.32S PROFIBUS DP module is directly integrated on Optyma-S solenoid valves manifold via a 37 poles connector, normally used for multipolar cable connection. Optyma-S solenoid valves connected to node must be PNP equivalent (final 02 in ordering code). The node can be easily installed also on solenoid valves manifold already mounted on equipment. Module can manage up to 32 solenoid valves, and, in the same time, a max number of 4 Input modules 5222.08S. PROFIBUS DP module recognizes automatically the presence of the Input modules on power on. Regardless of the number of Input modules connected, the managable solenoid valves are 32. Node power supply is made by a M12 4P male circular connector. The separation between node 24 VDC Power supply and outputs 24 VDC allows to switch off the outputs maintaning powered the node and inputs, if present. Connection to Bus PROFIBUS DP is possible via 2 M12 type B 5P male - female circular connectors; these two are connected in parallel and according to PROFIBUS Interconnection Technology (Version 1.1 : August 2001). The node address can be set using BCD numeration: 4 dip-switches for the units and 4 dipswitches for the tens. The module includes an internal terminating resistance that can be activated by a dip-switch. 2 1 3 4 Scheme / Overall dimensions and I/O layout : MAX 32 OUT 52 NETWORK connectors POWER SUPPLY connector PIN 1 2 3 4 DESCRIPTION +24 VDC (NODE & INPUTS) NC GND +24 VDC (OUTPUTS) M12 4P MALE M12 5P MALE M12 5P FEMALE 99 63 Ordering code Technical characteristics 9,6 - 19,2 - 93,75 - 187,5 - 500 - 1500 - 3000 - 6000 - 12000 Kbit/s Power supply Outputs Network Model Specifications Case Power supply connection Power supply voltage Node consumption (without inputs) Power supply diagnosis PNP equivalent outputs Maximum current for each output Maximum output number Max output simultaneously actuated Network connectors Baud rate Addresses, possible numbers Max nodes in net Bus maximum recommended length Bus diagnosis Configuration file IP protection grade Temperature range 5322.32S PROFIBUS DP Reinforced technopolymer M12 4P male connector (IEC 60947-5-2) +24 VDC +/- 10% 50 mA Green LED PWR +24 VDC +/- 10% 100 mA 32 32 2 M12 5P male-female connectors Type B From 1 to 99 100 (slave + master) 100 m at 12 Mbit/s - 1200 m at 9,6 Kbit/s Green LED + Red LED Available from our web site: http://www.pneumaxspa.com IP65 when assembled From 0° to +50° C 2 1 4 3 5 1 2 5 4 3 Receive / Transmit data -N, A-line PIN SIGNAL DESCRIPTION 1 VP Power supply plus, (P5V) 2 A-line 3 DGND Data Ground (reference potential to VP) 4 B-line Receive / Transmit data -plus, B-line 5 SHIELD Shield or PE
RkJQdWJsaXNoZXIy NzYzOTY1