CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice EtherNet/IP Module 1 Air distribution Solenoid valves manifold 1 | 441 Series 2200 "OPTYMA-S" - Serial systems EtherNet/IP module is directly integrated on Optyma-S solenoid valves manifold via a 37 poles connector, normally used for multipolar cable connection. Optyma-S solenoid valves connected to node must be PNP equivalent (final 02 in ordering code). The node can be easily installed also on solenoid valves manifold already mounted on equipment. Module can manage up to 32 solenoid valves, and, in the same time, a max number of 4 Input modules 5222.08S. The EtherNet/IP module, regardless the number of Input module connected, reports to have connected 8 Input modules. Regardless of the number of Input modules connected, the managable solenoid valves are 32. Node power supply is made by a M12 4P male circular connector. The separation between node 24 VDC Power supply and outputs 24 VDC allows to switch off the outputs maintaning powered the node and inputs, if present. Connection to Bus EtherNet/IP is possible via 2 M12 4P type D female circular connectors. These two connectors lead the signal to two different communication ports, so they are not connected in parallel. The node address is assigned during configuration. General: Ordering code 5722.32S.EI.A Scheme / Overall dimensions and I/O layout : M12 4P FEMALE M12 4P FEMALE NETWORK connectors M12 4P MALE POWER SUPPLY connector PIN 1 2 3 4 DESCRIPTION +24 VDC (NODE & INPUTS) +24 VDC (OUTPUTS) NC GND Technical characteristics 99 63 52 MAX 32 OUT 2 M12 4P female connectors Type D (IEC 61076-2-101) Power supply Outputs Network Model Specifications Case Power supply connection Power supply voltage Node consumption ( ) without inputs Power supply diagnosis PNP equivalent outputs Maximum current for each output Maximum output number Max output simultaneously actuated Network connectors Baud rate 5722.32S.EI.A The EtherNet/IP Specification Reinforced technopolymer M12 4P male connector (IEC 60947-5-2) +24 VDC +/- 10% 60 mA / OUT Green LED PWR Green LED +24 VDC +/- 10% 100 mA 32 32 100 Mbit/s 1 2 4 3 1 2 4 3 2 1 3 4 DESCRIPTION Ethernet Transmit High Ethernet Receive High Ethernet Transmit Low Ethernet Receive Low 1 2 3 4 TX+ RX+ TXRXPIN SIGNAL Max nodes in net Maximum distance between 2 nodes Bus diagnosis Configuration file IP protection grade Temperature range As an Ethernet Network 100 m Available from our web site: http://www.pneumaxspa.com IP65 when assembled From 0° to +50° C 2 bi-colors LEDs green/red for status + 4 LEDs for link & activity

RkJQdWJsaXNoZXIy NzYzOTY1