CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Configurator 1 Air distribution Solenoid valves manifold 1 | 446 Series 2200 "OPTYMA-S" - Serial systems __ __ __ ACCESSORIES W00 = Intermediate supply & exhaust module 0X0 = Diaphragm plug on pipe 1 00Y = Diaphragm plug on pipeE 3 Z00 = Diaphragm plug on pipe 5 0XY = Diaphragm plug on pipe 1 & 3 ZX0 = Diaphragm plug on pipe 5 & 1 Z0Y = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5,1 & 3 VALVES TYPE A = 5/2 Solenoid - Spring B = 5/2 Solenoid - Differential C = 5/2 Solenoid - Solenoid E = 5/3 CC Solenoid - Solenoid F = 2x3/2 NC-NC (= 5/3 OC) Solenoid - Solenoid G = 2x3/2 NO-NO (= 5/3 PC) Solenoid - Solenoid H = 2x3/2 NC-NO Solenoid - Solenoid I = 2x3/2 NO-NC Solenoid - Solenoid T = Free valve space plug NOTE: While configuring the manifold always be careful that the maximum number of electrical signals available is 32 The use of monostable valve mounted on a bistable base ( 2 electrical signals occupied for each position) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve without reconfiguring the PLC. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. I/O MODULE M8 (Requires 25 poles right endplate) __ __ __ __ __ __ S . . __ LEFT ENDPLATE A3 = 37 poles - Self feeding E3 = 37 poles - External feeding __ RIGHT ENDPLATE U0 = Closed U2 = 25 Poles __ __ . __ . . . . __ __ . . . INPUT MODULES A = No module D1= 8 M8 digital inputs module . ACCESSORIES CONFIGURATION _ _ __ __ MODUL CONFIGURATION Sub-base type Valve type SUB-BASE TYPE 3 = 2 Position Monostable sub base ø4 (2 electric signal used) 4 = 2 Position Bistable sub base ø4 (4 electric signals used) 5 = 2 Position Monostable sub base ø6 (2 electric signal used) 6 = 2 Position Bistable sub base ø6 (4 electric signals used) 7 = 2 Position Monostable sub base ø8 (2 electric signal used) 8 = 2 Position Bistable sub base ø8 (4 electric signals used) Manifold Layout configuration with serial systems SUB-BASE VARIANTS EMPTY = No variants (SUB-BASE STANDARD) 3 = Diaphragm plug on pipe 1 and 5 4 = Diaphragm plug on pipe 1 and 3 5 = Diaphragm plug on pipe 5 6 = Diaphragm plug on pipe 1, 3 and 5 7 = Diaphragm plug on pipe 1 8 = Diaphragm plug on pipe 3 and 5 9 = Diaphragm plug on pipe 3 32 OUT VERSION C3=CANopen® 32OUT D3=DeviceNet 32OUT P3=PROFIBUS 32OUT AA3=EtherCAT® 32OUT IA3=EtherNet / IP 32OUT NA3=PROFINET IO RT 32OUT K3=IO-Link 32OUT GA3=CC-Link IE Field Basic 32OUT

RkJQdWJsaXNoZXIy NzYzOTY1