CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Electric and electro-pneumatic cut off module 1 Air distribution Solenoid valves manifold 1 | 462 Series 2500 "OPTYMA-F" - Accessories Ordering code WORKING PRINCIPLE / SIMPLIFIED FUNCTIONAL DIAGRAM 1 3 4 This module uses an external power supply (+24VDC) to manage the solenoid valves. The output signal from serial node / multi-pole connection is used as command signal: when it is high the +24VDC will be present at the module output. If you want to cut off the power supply to a group of 2 valves it is sufficient to take away the +24VDC provided to the module by the M8 connector. Please note: It is possible to use more modules to interrupt all the command signals, simply by inserting them before the signals to interrupt and after the signals already interrupted. In particular this module is fitted with a M8 3 pins connector: +24V, not connected, GND. PIN DESCRIPTION 1 +24 VDC 4 NOT CONNECTED 3 GND General : Each Optyma-F manifold allows you to manage 32 command signals for the solenoid valves. Optyma-F serial nodes (CANopen®, DeviceNet, PROFIBUS DP, EtherCAT®, PROFINET IO RT, EtherNet/IP and CC-Link IE Field Basic) have a single pin for the power supply of the solenoid valves. So if you want to interrupt the power supply of one valve it is necessary to interrupt all the valves. The additional power supply module allows you to interrupt at the same time the first 2, 4, 6 o 8 available command signals for the valves after the module itself according to the selected device version. The additional power supply moduleis particularly useful also when you use control signals that block the valves. This application is effective both with serial management and multi-pole connection of the manifolds. Furthermore, the electro-pneumatic cut off module allows you to interrupt the air flow that feeds the 12/14 pilots coming from upstream. A threaded connection port incorporated in the module allows to pneumatically feed each pilots of a limited number of solenoid valves downstream. This module has the same characteristics of an intermediate supply and exhaust module and fits directly into the Optyma-F series solenoid valve manifolds. 2530.11.2A = 2 positions 2530.11.4A = 4 positions 2530.11.6A = 6 positions 2530.11.8A = 8 positions A 33 139.2 12/14 G1/8” 6 G1/4” G1/4” 19.5 19.5 G1/4” M8 39 44 7 36 19 10.25 44.3 5 1 3 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN ... IN 32 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT ... OUT 32 GND 3 4 1

RkJQdWJsaXNoZXIy NzYzOTY1