CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 8 Input/Output Module 1 Air distribution Solenoid valves manifold 1 | 467 Series 2500 "OPTYMA-F" - Accessories Ordering code By the user Attention: The output connections are not protected against short-circuit. Please pay attention when wiring (avoid Pin 4 being connected to Pin 3 or Pin 1). General : 2530.08F Output features: Each connection can accept either two wire (switches, magnetic switches, pressure switches, etc.) or three wire connections (photocells, electronic end of stroke sensors, etc.) If +24VDC is required on at Pin 1 of each connector, it is possible to provide this via the through-line pin of the multi-pole connector. I.E : Pin 25 of the 25 pin multi-pole connector (code 2530.02.25P or 2530.12.25P) Pin 36-37 of the 37 pin multi-pole connector (code 2530.02.37P or 2530.12.37P) Input features: DIAGNOSTIC GREEN LED VOLTAGE ON THROUGH-LINE GREEN LED INPUT/OUTPUT Please note: If the manifold is connected by a multi-core connection, each connection can be used as either an input or an output, while if the manifold is connected to a serial node the connections can only be used as an output. It is possible to connect the manifold to up to two I/O modules. Using the 2530.03.25P output terminal it is possible to make any electrical signals not used by valves available on a 25 sub-D female connector at the right end of the manifold. It is possible to then join a multi-core cable to link to the next manifold, or connect directly to one or two I/O modules. The I/O modules can accept input or output signals, depending upon what is connected. Each I/O module includes 8 diagnostic LEDs which indicate the presence of an Input / Output signal for each connector. Please note: For an LED to function, a signal of at least +15VDC must be present on pin 4 of the connector. If this signal is lower, the LED will not light, this does not compromise the normal Input / Output function of the unit. Overall dimensions and I/O layout : 81.4 M8 CONNECTOR 3 POLES FEMALE M8 CONNECTOR 3 POLES FEMALE PIN DESCRIPTION 1 +24 VDC 4 INPUT/OUTPUT 3 GND 1 4 3 49 55.2 76.6 81 General characteristics Model Case I/O Connector PIN1 voltage (connector used as Input) PIN 4 voltage diagnosis Node consumption (Outlets excluded) Outlets voltage Input voltage Maximum outlet current Maximum Input/Output Multiconnector max. Current Connections to manifold Maximum n. of moduls Protection degree Ambient temperature 2530.08F Reinforced technopolymer M8 connector 3 poles female (IEC 60947-5-2) Green LED 7mA per each LED with 24 VDC signal +23,3 VDC (serial) /by the user (multipolar) Depend by the using 100 mA (serial) / 400 mA (multipolar) 8 per module 100 mA Direct connection to 25 poles connector 2 IP65 when assembled from -0° to +50° C

RkJQdWJsaXNoZXIy NzYzOTY1