CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Configurator 1 Air distribution Solenoid valves manifold 1 | 472 Series 2500 "OPTYMA-F" - Accessories NOTE: Manifold Layout configuration __ __ F . . __ LEFT ENDPLATE A2 = 25 poles - Self feeding A3 = 37 poles - Self feeding E2 = 25 poles - External feeding E3 = 37 poles - External feeding AM = 16 signals - Self feeding EM = 16 signals - External feeding ACCESSORIES CONFIGURATION __ __ MODUL CONFIGURATION __ MULTIPOINT CONNECTION MP = PNP 24 V DC MN = NPN 24 V DC MA = 24 V AC RIGHT ENDPLATE U0 = Closed U2 = 25 Poles U3 = 37 Poles __ __ . __ . . . I/O MODULE M8 (Requires 25 poles right endplate) . . . . . . . Valve type Sub-base type ACCESSORIES U2 = Electric and electro-pneumatic cut off module 2 positions K2 = Electric and electro-pneumatic cut off module 2 positions with external pilot U4 = Electric and electro-pneumatic cut off module 4 positions K4 = Electric and electro-pneumatic cut off module 4 positions with external pilot U6 = Electric and electro-pneumatic cut off module 6 positions K6 = Electric and electro-pneumatic cut off module 6 positions with external pilot U8 = Electric and electro-pneumatic cut off module 8 positions K8 = Electric and electro-pneumatic cut off module 8 positions with external pilot W = Intermediate supply & exhaust module X = Diaphragm plug on pipe 1 Y = Diaphragm plug on pipe 3 Z = Diaphragm plug on pipe 5 XY = Diaphragm plug on pipe 1 & 3 ZX = Diaphragm plug on pipe 5 & 1 ZY = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5, 1 & 3 SHORT CODE FUNCTION / CONNECTION : A1= 5/2 SOL.-SPRING + BASE TYPE 1 (1 electrical signal occupied) A2= 5/2 SOL.-SPRING + BASE TYPE 2 (2 electrical signals occupied) B1= 5/2 SOL.-DIFFERENTIAL + BASE TYPE 1 (1 electrical signal occupied) B2= 5/2 SOL.-DIFFERENTIAL + BASE TYPE 2 (2 electrical signals occupied) C2= 5/2 SOL.-SOL. + BASE TYPE 2 (2 electrical signals occupied) E2= 5/3 CC SOL.-SOL. + BASE TYPE 2 (2 electrical signals occupied) F2= 2x3/2 NC-NC (= 5/3 OC) SOL.-SOL.+BASE TYPE 2 (2 electrical signals occupied) G2= 2x3/2 NO-NO (= 5/3 PC) SOL.-SOL.+BASE TYPE 2 (2 electrical signals occupied) H2= 2x3/2 NC-NO SOL.-SOL. + BASE TYPE 2 (2 electrical signals occupied) I2= 2x3/2 NO-NC SOL.-SOL. + BASE TYPE 2 (2 electrical signals occupied) T1= FREE VALVE SPACE PLUG + BASE FOR MONOSTABLE VALVE T2= FREE VALVE SPACE PLUG + BASE FOR BISTABLE VALVE Well-tried component B10d 50.000.000 Series 2500 OPTYMA-F solenoid valve manifolds managed by multipoint connection are “well tried components” - The product is a well-tried product for a safety-related application according to ISO 13849-1. - The relevant basic and well-tried safety principles according ISO 13849-2 for this product are fulfilled. - The suitability of the product for a precise application must be verified and confirmed by the user. While con guring the manifold always be careful that the maximum number of electrical signals available is: 32 when an input 37 poles endplate is used. 22 when an input 25 poles endplate is used. The use of monostable valve mounted on a base type 2 ( 2 electrical signals occupied ) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. If it is necessary to interrupt more than one conduit in the same time then put in line the letters which identi es the position (for exemple : regarding the 3 & 5 conduits, put the Y & Z letters). Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module.

RkJQdWJsaXNoZXIy NzYzOTY1