Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution 1 | 509 Solenoid valves manifold Series 2300 ENOVA® ►Solenoid-Solenoid 2x2/2 Bistable-N.C. - N.O. Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Pilot pressure (bar) 2,5 ... 7 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 700 Response time according to ISO 12238, activation time (ms) 9 Response time according to ISO 12238, deactivation time (ms) 30 Weight 130 g 90 3,5 max. 12,5 32,75 22 ØA 77 Coding: 230C.42.45.35.V C CONNECTION ØA 4 = Quick connection for tube Ø4 6 = Quick connection for tube Ø6 8 = Quick connection for tube Ø8 V VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN SHORT CODE N4 SHORT CODE N6 SHORT CODE N8 14 82/84 12/14 4 2 11 1 12 ►Solenoid-Solenoid 2x2/2 Bistable-N.O. - N.O. Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Pilot pressure (bar) 2,5 ... 7 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 700 Response time according to ISO 12238, activation time (ms) 9 Response time according to ISO 12238, deactivation time (ms) 30 Weight 130 g 90 3,5 max. 12,5 32,75 22 ØA 77 Coding: 230C.42.55.35.V C CONNECTION ØA 4 = Quick connection for tube Ø4 6 = Quick connection for tube Ø6 8 = Quick connection for tube Ø8 V VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN SHORT CODE M4 SHORT CODE M6 SHORT CODE M8 14 82/84 12/14 4 2 11 1 12
RkJQdWJsaXNoZXIy NzYzOTY1