Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 AIR DISTRIBUTION Solenoid valves manifold 1 | 511 Series 2500 "OPTYMA-T" - Serial systems General: Ordering code MAX 32 OUT 68 62.2 53 82 Technical characteristics 5725.32T.CL.A M12 4P FEMALE M12 4P FEMALE 1 2 4 3 1 2 4 3 Scheme / Overall dimensions and I/O layout : NETWORK connectors DESCRIPTION Ethernet Transmit High Ethernet Receive High Ethernet Transmit Low Ethernet Receive Low 1 2 3 4 TX+ RX+ TXRXPIN SIGNAL POWER SUPPLY connector M12 4P MALE +24 VDC (OUTPUTS) Model Specifications Case Power supply connection Power supply voltage Node consumption (without inputs) Power supply diagnosis PNP equivalent outputs Maximum current for each output Maximum output number Max output simultaneously actuated Network connectors Baud rate Max nodes in net Maximum distance between 2 nodes Bus diagnosis Configuration file IP protection grade Temperature range 5725.32T.CL.A Reinforced technopolymer M12 4P male connector (IEC 60947-5-2) +24 VDC ± 10% 60 mA Green LED PWR / Green LED OUT +24 VDC ± 10% 100 mA 32 32 100 Mbit/s As an Ethernet Network 100 m 1 green and 1 red LED for status + 2 LEDs for link & activity Available from our web site: http://www.pneumaxspa.com IP65 when assembled From 0° to +50° C Power supply Outputs Network 2 M12 4P female connectors Type D (IEC 61076-2-101) 2 1 3 4 1 2 NC 3 GND 4 PIN DESCRIPTION +24 VDC (NODE & INPUTS) CC-Link IE Field Basic module is directly integrated on Optyma-T solenoid valves manifold via a 37 poles connector, normally used for multipolar cable connection. Optyma-T solenoid valves connected to node must be PNP equivalent (final 02 in ordering code). The node can be easily installed also on solenoid valves manifold already mounted on equipment. Module can manage up to 32 solenoid valves, and, in the same time, a max number of 8 Input modules 5225.08T or a max number of 8 Input modules 5225.12T. The CC-Link IE Field Basic module, regardless the number of Input module connected, reports to have connected 8 Input modules. Regardless of the number of Input modules connected, the managable solenoid valves are 32. Node power supply is made by a M12 4P male circular connector. The separation between node 24 VDC Power supply and outputs 24 VDC allows to switch off the outputs maintaning powered the node and inputs, if present. Connection to Bus CC-Link IE Field Basic is possible via 2 M12 4P type D female circular connectors. These two connectors lead the signal to two different communication ports, so they are not connected in parallel. The node address is assigned during configuration. CC-Link IE Field Basic Specification CC-Link IE Field Basic Module
RkJQdWJsaXNoZXIy NzYzOTY1