Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 2 analogue Input module 1 Air distribution Solenoid valves manifold 1 | 515 Series 2500 "OPTYMA-T" - Serial systems Module 1 Module 1 Module 2 68 136 This module is fitted with two M8 3 pin female connectors. With this module is possible to read two analogue inputs (voltage or current). The inputs are sampled at 12 bit. For practicality the sampled value is transmitted with 16 bit, of which the four less significant are fixed at zero. Available models: 5225.2T.00T (voltage signal 0 - 10V); 5225.2T.01T (voltage signal 0 - 5V); 5225.2C.00T (current signal 4 - 20mA); 5225.2C.01T (current signal 0 - 20mA). Each module includes a 300 mA self-mending fuse. Should a short circuit or a overcharge (overall current >300mA) occur the safety device intervenes cutting the 24VDC power supply to all M8 connectors on the module and switching off the green LED PWR. Any other Input module connected to the node will remain powered and will function correctly. Once the cause of the fault is removed the green LED lights up indicating the ON state and the node will re-start to operate. This module is counted as four 8 digital Inputs modules. The Maximum number of 2 analogue Inputs modules supported is ® 1 for CANopen , DeviceNet, ® PROFIBUS DP and EtherCAT . The Maximum number of 2 analogue Inputs modules supported is 2 for PROFINET IO RT, EtherNet/IP and Powerlink. General : Scheme / Overall dimensions and I/O layout : GREEN LED POWER M8 3P FEMALE CONNECTOR GREEN LED INPUTS Ordering code 5225.2 _ . _T 1 4 3 PIN DESCRIPTION 1 +24 VDC 4 INPUT 3 GND
RkJQdWJsaXNoZXIy NzYzOTY1