Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distributiOn Solenoid valves manifold 1 | 521 Series 2300 ENOVA® - Serial systems ►PROFIBUS DP protocol node Scheme / Overall dimensions and I/O layout PIN 1 2 3 4 5 4 1 3 2 PIN 1 2 3 0 V 4 3 2 4 5 1 4 1 3 2 5 90 32.5 50 60 Receive / Transmit data -N, A-line VP A-line DGND Data Ground (reference potential to VP) B-line Receive / Transmit data -plus, B-line SHIELD Shield or PE Power supply plus, (P5V) DESCRIPTION POWER SUPPLY connector M12A 4P MALE SIGNAL DESCRIPTION + 24 V DC (LOGICS AND INPUTS) + 24 V DC (OUTPUTS) NETWORK connectors M12A 5P FEMALE M12A 5P MALE MAX 22 OUT N.C. Technical characteristics Model 5323.22 specifications PrOFibus dP Case reinforced technopolymer Power supply Power supply connection M12 4P male connector Power supply voltage +24 VdC +/- 10% node consumption (without inputs) 50 mA Power supply diagnosis Green LEd PWr Outputs PnP equivalent outputs +24 VdC +/- 10% Max. current for output 100 mA Maximum output number 22 or 16 if node is fitted with 2 input modules Max. output simultaneously actuated 22 network network connectors 2 M12 5P connectors male-female baud rate 125 - 250 - 500 Kbit/s Addresses possible numbers From 1 to 63 Maximum nodes number in network 64 (slave + master) bus maximum recommended length 100 m at 500 Kbit/s bus diagnosis Green LEd + red LEd Configuration file Available from our web site http://www.pneumaxspa.com Protection degree iP65 when assembled temperature range From 0 °C to +50 °C Coding: 5323.22 PrOFibus dP node is directly integrated on Enova® solenoid valves manifold via a 25 poles connector, normally used for multipin cable connection. Enova® solenoid valves connected to node must be PnP equivalent (final 02 in ordering code). the node can be easily installed also on solenoid valves manifold already mounted on equipment. node can manage up to 22 solenoid valves, when is connected 0 or 1 inPut modules, or 16 if node is fitted with 2 inPut modules. the max number of inPut modules 5200.08, is 2. PrOFibus dP node recognizes automatically the presence of the input modules on power on. node power supply is made by a M12 4P male circular connector. the separation between node 24 V dC Power supply and outputs 24 V dC allows to switch off the outputs maintaning powered the node and inputs, if present. Connection to bus PrOFibus dP is possible via 2 M12 type b 5P male - female circular connectors; these two are connected in parallel and according to PrOFibus interconnection technology (Version 1.1 : August 2001). the node address can be set using bCd numeration: 4 dip-switches for the units and 4 dip-switches for the tens. the node includes an internal terminating resistance that can be activated by a dip-switch.
RkJQdWJsaXNoZXIy NzYzOTY1