CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Solenoid valves manifold 1 | 522 Series 2300 ENOVA® - Inputs and outputs modules ►8 input module Scheme / Overall dimensions and I/O layout PIN INPUT + 24 V DC 0 V 1 4 3 1 4 3 60 120 180 Module1 Module 1 Module 2 Module 1 Module 2 Module 3 GREEN LED POWER M8 3P FEMALE CONNECTOR ORANGE LED INPUTS ORANGE LED INPUTS DESCRIPTION Coding: 5200.08 M8 digital inputs module provides 8 M8, 3 pins, female connectors. Inputs have PNP logic, + 24 V DC ± 10%. It is possible to connect 2 wires devices (e.g. switches, magnetic limit switches, pressure switches, etc.) as well as 3 wires devices (e.g. proximity sensors, photocells, electronic magnetic limit switches, etc.). The maximum current available for all 8 onputs is 200 mA. Each module includes a 200 mA resettable fuse. If a short circuit or a overcharge (overall current >200 mA) occur the safety device acts cutting the 24 VDC power supply to all M8 connectors on the module and switching off the green LED PWR. Any other input module connected to the node will remain powered and will function correctly. Once the cause of the fault disappears the green led PWR light up indicating the ON state and the node will re-start to operate. The maximum number of Input modules supported is 3 for CANopen® and DeviceNet, 2 for PROFIBUS DP.

RkJQdWJsaXNoZXIy NzYzOTY1