CATGEN-EN

EtherNet/IP - EtherCAT® - PROFINET IO RT modules Solenoid valves manifold Series 3000 - Serial systems 1 AIR DISTRIBUTION 1 | 544 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Case Reinforced technopolymer Power supply Power supply connection M12 4 P male connector (IEC 60947-5-2) Power supply voltage +24 VDC +/- 10% Node consumption (without inputs) 100 mA Power supply diagnosis Green LED PWR / Green LED OUT Network Network connectors 2 M12 4 P female connectors type D (IEC 61076-2-101) Baud rate 100 Mbit/s Addresses possible numbers As an IP address Maximum distance between 2 nodes 100 m Bus diagnosis 2 bicolor red / green LEDs + 4 LEDs for link & activity Configuration file Available from our web site http://www.pneumaxspa.com IP Rating IP65 when assembled Temperature range From 0°C to +50°C Technical characteristics Ordering code 5730.128.48EI 5730.128.48EC 5730.128.48PN General - EtherNet/IP - EtherCAT® - PROFINET IO RT slave modules 5730.128.48PN, 5730.128.48EC e 5730.128.48EI nodes handle up to 128 inputs and outputs, both divided into 16 bytes. Output typologies include solenoid valves, digital outputs (e.g. 5130.08.M8) and analog outputs (e.g. 5130.2T.00). Connectable input types include digital inputs modules (e.g. 5230.08.M8), analog inputs modules (e.g. 5230.2T.00) and Pt100 inputs modules (e.g. 5230.4P.02). Optional modules can be connected to the manifold in any order and configuration, provided that modules are installed starting from the node and optional position modules left to furthest end. Electric power must be supplied via circular M12 4 pins male type A connector. The separation between 24VDC supply of the node and 24VDC of the outputs allows to turn off outputs leaving the node and eventual inputs operational. The network connection is achieved via two circular female connectors (M12 4 pins, type D); these two circular connectors belong to two separate communication ports; hence they are not connected in parallel. In 5730.128.48PN, 5730.128.48EC and 5730.128.48EI part numbers the first 48 out of 128 outputs, corresponding to less significant 6 bytes, are permanently allocated to the solenoid valve positions, regardless how many they are and how many valves are installed. The remaining 80 outputs can be used to handle optional output modules. Bytes allocation to optional modules is done automatically. When more than 64 inputs are needed and current coming from 24VDC rail is higher than 2.5A, the use of additional power supply module (part number 5030.M12) is mandatory. 5030.M12 additional power supply module must be plugged-in upstream to the modules exceeding the above stated current limit, therefore close to the network node. On the other hand, whenever 64 outputs are used and further optional outputs modules are required, if total computed simultaneous current is higher than 2A, the 5030.M12 module is mandatory. 5030.M12 module is plugged-in upstream to additional modules; it will supply electrical power to downstream modules. If 5030.M12 module has been already integrated to supply inputs modules, it is not necessary to install a second one, since it already supplies outputs modules. Scheme / Overall dimensions and I/O layout 42 90 PIN SIGNAL DESCRIPTION 1 TX + Ethernet Transmit High 2 RX + Ethernet Receive High 3 TX - Ethernet Transmit Low 4 RX - Ethernet Receive Low POWER SUPPLY connector PIN DESCRIPTION 1 + 24 VDC (NODE & INPUTS) 2 NC 3 GND 4 +24 VDC (OUTPUTS) M12A 4P MALE 4 1 3 2 28 NETWORK connectors 3 2 4 1 M12D 4P FEMALE 3 2 4 1 M12D 4P FEMALE

RkJQdWJsaXNoZXIy NzYzOTY1