CATGEN-EN

M8 - M12 digital inputs modules Solenoid valves manifold Series 3000 1 AIR DISTRIBUTION 1 | 546 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice General - 8 M8 digital inputs module M8 digital inputs module provides 8 M8, 3 pins, female connectors. Inputs have PNP logic, 24VDC ± 10%. It is possible to connect 2 wires devices (e.g. switches, magnetic limit switches, pressure switches, etc...) as well as 3 wires devices (e.g. proximity sensors, photocells, electronic magnetic limit switches, etc.). Inputs module power supply is provided by 24VDC power input on the serial system (type A, 4 pin M12 power connector, pin 1) or by module 5030.M12, in case it were installed upstream of the inputs module. Maximum overall available current for all 8 inputs on 24VDC rail is 300mA, since every module is equipped with an auto-resettable fuse with 300mA threshold, thus, in case of overload or short circuit, 24VDC rail is interrupted and, as a consequence, all 8 inputs 24VDC is turned off along with green PWR LED. Other eventually connected inputs modules stays operational. Removing fault cause, green PWR LED gets back in on status and module becomes operational again. The M8 digital inputs module takes up 8 input bits of the serial node installed on the manifold. Ordering code 5230.08.M8 General - 8 M12 digital inputs module Ordering code 5230.08.M12 Scheme / Overall dimensions and I/O layout 42 90 28 M12 5P female connector PIN DESCRIPTION 1 + 24 VDC (INPUTS) 2 INPUT B 3 GND 4 INPUT A 5 NC Scheme / Overall dimensions and I/O layout 42 90 28 M8 3P female connector 4 3 1 PIN DESCRIPTION 1 + 24 VDC (INPUTS) 3 GND 4 INPUT M12A 5P FEMALE 3 2 4 5 1 M12 digital inputs module provides 4 M12, 5 pins, female connectors. Inputs have PNP logic, 24VDC ± 10%. Every connector takes two independent input channels. It is possible to connect 2 wires devices (e.g. switches, magnetic limit switches, pressure switches, etc...) as well as 3 wires devices (e.g. proximity sensors, photocells, electronic magnetic limit switches, etc.). Inputs module power supply is provided by 24VDC power input on the serial system (type A, 4 pin M12 power connector, pin 1) or by module 5030.M12, in case it were installed upstream of the inputs module. Maximum overall available current for all 4 connectors on 24VDC rail is 300mA, since every module is equipped with an auto-resettable fuse with 300mA threshold, thus, in case of overload or short circuit, 24VDC rail is interrupted and as a consequence all inputs 24VDC is turned off along with green PWR LED. Other eventually connected inputs modules remains operational. Removing fault cause, green PWR LED gets back in on status and module becomes operational again. The M12 digital inputs module takes up 8 input bits of the serial node installed on the manifold.

RkJQdWJsaXNoZXIy NzYzOTY1